Milwaukee Instruments dissolved oxygen meters, sold and supported in Australia by Milwaukee Meters. Choose the MW600 PRO portable meter for fish farms, ponds and teaching labs, the waterproof MW605 MAX with a galvanic probe and data logging for field work, or the MW190 MAX bench meter for the laboratory. Probes, membranes and calibration solutions for each model are listed below.

Dissolved Oxygen / Temperature MAX Portable Meter
O2 Range*: 0.0 to 45.00 mg/L (ppm)

Dissolved Oxygen / Temperature Laboratory Bench Meter
...
Standard Portable Dissolved Oxygen Meter
O2 Range: 0.0 to 19.9 mg/L
All three Milwaukee meters read dissolved oxygen in mg/L (ppm) with automatic temperature compensation. The MW600 PRO is the simple, low-cost choice for spot checks in ponds, tanks and classrooms. The MW605 MAX adds a waterproof body, % saturation, salinity and altitude settings and data logging for field and saltwater work. The MW190 MAX is the laboratory bench version with the same 0–45 mg/L range and a PC connection.
| Model | What you get |
|---|---|
| MW600 PRO Portable | 0.0–19.9 mg/L, ±1.5% FS. MA840 polarographic probe, 3 m cable. Compensates for temperature (0–30 °C). No data logging. |
| MW605 MAX Portable, IP67 | 0.00–45.00 mg/L, 0–300% saturation. MA860 galvanic probe, ready at power-on. Compensates for temperature, salinity (0–40 g/L) and altitude. Logs 1,000 records, USB. |
| MW190 MAX Bench | 0.00–45.00 mg/L, 0–300% saturation. MA845 polarographic probe, 2 m cable. Compensates for temperature, salinity (0–40 g/L) and altitude. Logs 50 samples, RS232/USB. |
Calibrate every model at zero in zero oxygen calibration solution and at 100% in water-saturated air. Polarographic probes also need fresh membranes and electrolyte from time to time. More spares are in probes and electrodes and calibration standards.
| Meter | Probe, membranes and solutions |
|---|---|
| MW600 PRO | MA840 DO probe, MA841 membrane set (5), MA9071 electrolyte, zero oxygen calibration solution |
| MW605 MAX | MA860 galvanic probe and MA861 membranes (ask us), zero oxygen calibration solution |
| MW190 MAX | MA845 DO probe (membranes supplied with the meter), zero oxygen calibration solution |
Milwaukee Meters is part of Pacific Sensor Technologies. To compare Milwaukee with Hanna and GOnDO dissolved oxygen meters, including models that also measure BOD, see Pacific Sensor Tech’s dissolved oxygen meter range.
Choose the MW600 PRO for simple spot checks in ponds, fish tanks and teaching labs. It reads 0.0 to 19.9 mg/L. Choose the MW605 MAX for field and saltwater work. It is waterproof (IP67), reads up to 45 mg/L and 300% saturation, and logs up to 1,000 readings. Choose the MW190 MAX for a laboratory bench with a PC connection.
The MW600 PRO uses the MA840 polarographic probe. It is refillable: you replace the screw-on membrane caps and MA9071 electrolyte as part of normal care. The MW605 MAX uses the MA860 galvanic probe, which needs no conditioning, so the meter is ready to measure as soon as it is switched on.
All three meters calibrate at 0% in Zero oxygen solution and at 100% in water-saturated air. The MW600 PRO is calibrated manually at both points with the screwdriver supplied. The MW605 MAX accepts one or two points. The MW190 MAX calibrates automatically at one point (zero) or two points with the slope in air.
The MW605 MAX and MW190 MAX do. You enter salinity from 0 to 40 g/L and altitude up to 4,000 m in Setup, and temperature is compensated automatically. The MW600 PRO compensates for temperature only, from 0 to 30 °C, so it suits fresh water.
The MW605 MAX stores up to 1,000 records, on demand, on stability or at intervals, and exports them over micro USB. The MW190 MAX logs up to 50 samples and connects to a PC over RS232/USB. The MW600 PRO shows a live reading only.
Replace the membrane when it is damaged or the reading drifts, using the MA841 set of 5, and top up with MA9071 electrolyte. Keep Zero oxygen solution for calibration. The MA840 is the complete replacement probe.