Milwaukee Dissolved Oxygen Meters

Milwaukee Instruments dissolved oxygen meters, sold and supported in Australia by Milwaukee Meters. Choose the MW600 PRO portable meter for fish farms, ponds and teaching labs, the waterproof MW605 MAX with a galvanic probe and data logging for field work, or the MW190 MAX bench meter for the laboratory. Probes, membranes and calibration solutions for each model are listed below.

ALL PRICES IN THIS WEBSITE ARE EXCLUSIVE OF AUSTRALIAN GST
GST will be added at the checkout for all online orders

Choosing a Milwaukee dissolved oxygen meter

All three Milwaukee meters read dissolved oxygen in mg/L (ppm) with automatic temperature compensation. The MW600 PRO is the simple, low-cost choice for spot checks in ponds, tanks and classrooms. The MW605 MAX adds a waterproof body, % saturation, salinity and altitude settings and data logging for field and saltwater work. The MW190 MAX is the laboratory bench version with the same 0–45 mg/L range and a PC connection.

ModelWhat you get
MW600 PRO
Portable
0.0–19.9 mg/L, ±1.5% FS. MA840 polarographic probe, 3 m cable. Compensates for temperature (0–30 °C). No data logging.
MW605 MAX
Portable, IP67
0.00–45.00 mg/L, 0–300% saturation. MA860 galvanic probe, ready at power-on. Compensates for temperature, salinity (0–40 g/L) and altitude. Logs 1,000 records, USB.
MW190 MAX
Bench
0.00–45.00 mg/L, 0–300% saturation. MA845 polarographic probe, 2 m cable. Compensates for temperature, salinity (0–40 g/L) and altitude. Logs 50 samples, RS232/USB.

Probes, membranes and solutions for each model

Calibrate every model at zero in zero oxygen calibration solution and at 100% in water-saturated air. Polarographic probes also need fresh membranes and electrolyte from time to time. More spares are in probes and electrodes and calibration standards.

MeterProbe, membranes and solutions
MW600 PROMA840 DO probe, MA841 membrane set (5), MA9071 electrolyte, zero oxygen calibration solution
MW605 MAXMA860 galvanic probe and MA861 membranes (ask us), zero oxygen calibration solution
MW190 MAXMA845 DO probe (membranes supplied with the meter), zero oxygen calibration solution

Comparing Milwaukee with other brands?

Milwaukee Meters is part of Pacific Sensor Technologies. To compare Milwaukee with Hanna and GOnDO dissolved oxygen meters, including models that also measure BOD, see Pacific Sensor Tech’s dissolved oxygen meter range.

Frequently Asked Questions

Which Milwaukee dissolved oxygen meter should I choose?

Choose the MW600 PRO for simple spot checks in ponds, fish tanks and teaching labs. It reads 0.0 to 19.9 mg/L. Choose the MW605 MAX for field and saltwater work. It is waterproof (IP67), reads up to 45 mg/L and 300% saturation, and logs up to 1,000 readings. Choose the MW190 MAX for a laboratory bench with a PC connection.

What is the difference between the MW600 PRO and MW605 MAX probes?

The MW600 PRO uses the MA840 polarographic probe. It is refillable: you replace the screw-on membrane caps and MA9071 electrolyte as part of normal care. The MW605 MAX uses the MA860 galvanic probe, which needs no conditioning, so the meter is ready to measure as soon as it is switched on.

How do I calibrate a Milwaukee DO meter?

All three meters calibrate at 0% in Zero oxygen solution and at 100% in water-saturated air. The MW600 PRO is calibrated manually at both points with the screwdriver supplied. The MW605 MAX accepts one or two points. The MW190 MAX calibrates automatically at one point (zero) or two points with the slope in air.

Do Milwaukee DO meters correct for salinity and altitude?

The MW605 MAX and MW190 MAX do. You enter salinity from 0 to 40 g/L and altitude up to 4,000 m in Setup, and temperature is compensated automatically. The MW600 PRO compensates for temperature only, from 0 to 30 °C, so it suits fresh water.

Which Milwaukee DO meters log data?

The MW605 MAX stores up to 1,000 records, on demand, on stability or at intervals, and exports them over micro USB. The MW190 MAX logs up to 50 samples and connects to a PC over RS232/USB. The MW600 PRO shows a live reading only.

What spare parts does the MW600 PRO need?

Replace the membrane when it is damaged or the reading drifts, using the MA841 set of 5, and top up with MA9071 electrolyte. Keep Zero oxygen solution for calibration. The MA840 is the complete replacement probe.